dzl chain grate coal fired steam boiler

How to avoid the chemical processing enterprises boiler boiler water pollution chemical processing companies how to avoid water pollution? It is well known in the food production process, many sectors need to use boilers, such as cooking, faced with the problem of sewage treatment, also with a certain level sterilization, dry, wine and so on. In the country's growing emphasis on environmental protection, continue to increase supervision of enterprises under the enterprise adoption of what approach to avoiding disadvantages, complete sustainable development? Primary, flue gas collection equipment processing equipment. Since SMEs by financial constraints, skills, and other places, a time can not be cut all the transformation, it is possible, after passing through the coal-fired boiler exhaust gas purifying exhaust purification device tail device, such as a fume hood, an exhaust gas collection processing device, effectively to prevent the direct discharge of black smoke, a serious impact on the surrounding environment. Second, clean power conversion, such as coal gas, coal to electricity. I learned that a beer factory invested more than 10 million will replace all coal-fired boilers, gas-fired. Now, 180 tons of dzl chain grate coal fired steam boiler plant now farewell all coal, burning a low nitrogen gas cleaning switch, effectively reduce pollution. And compared with previous coal-fired boilers, coal saving more than 80,000 tons per year business. Again, the original boiler for energy saving, skills promotion. Programming with the furnace arch, adjust the secondary air to optimize the planning aspects of the planning grate, uniformity of air distribution, so that plenty of fuel burned, burning power progress. It is understood, Shanxi, a business research and development of environmentally friendly gas-solid two-fired boiler using low-grade nitrogen incineration furnace desulfurization, flue gas purification tail, the whole active control and other skills to complete energy efficient, which means that the stop, auto-run and clean intent emissions. Eventually, equipment sewage treatment facilities. Many food processing plants because of waste water, untreated sewage discharge and perhaps willful discharge, was ordered rectification probably ordered the closure of news after another. Because food processing wastewater organics, heavy metals, a high concentration of suspended solids, wanton discharge highly contaminated water, soil and living environment. All in all, China's boiler industry, neither sunrise industry, not a sunset industry, food processing industry but indispensable industry. However, along with constantly promote the national energy saving policy, whether it is food processing enterprises, is still food machinery manufacturing enterprises, must always assume social responsibility, uphold the concept of energy saving, reduction may reduce pollutant emissions.

6 tons adjusting a combustion gas dzl chain grate coal fired steam boiler, normal combustion boiler three basic aspects of indicators include a uniform supply of the fuel, reasonable ventilation, adjustment the combustion. 1, to maintain the high temperature of the combustion chamber temperature of the upper layer is preferably in the 1100 ~ 1300 ℃, flame orange in color. Flame reddish color indicates that the amount is not enough to the wind, the color white indicates that excessive wind. It should be appropriately adjusted. 2, fuel ash to reduce ash content in the combustibles to be below 10%. 3, reducing the temperature of the boiler flue gas exhaust gas temperature should be controlled below 200 ℃. 4, holding furnace negative excess air boiler is 1.2 to 1.4, by adjusting the balance of the blowers to maintain the furnace pressure is -20 ~ -30Pa. 5, the thermal efficiency of the boiler to improve the thermal efficiency of the boiler should be kept above 60%. II. Combustion Adjustment 1, the amount of fuel to air required for combustion and the amount of a reasonable distribution. Ventilation should first increase the amount of fuel increases, it should first reduce the amount of fuel supply reduced ventilation. 2, the thickness of the seam and seam thickness configuration grate speed is 80 ~ 120mm grate speed at high, middle and low profile configuration of several commonly used methods:. 9a rapid combustion of thin seam b c thick seam in low combustion. 3 thick seam combustion speed, the segment with the wind blowing principle: burn promoting intermediate ends. That is, after the coal into the coal starts to warm up the shutter, fire line front arch, the primary combustion zone, the middle grate to burn the rear grate zone. Normal combustion conditions are: fuel from the coal at the beginning of the fire shutter 300mm, uniform flames, the fire bed formation, at the end of combustion from the end of the grate 300 ~ 500mm. 4. maintain proper furnace temperature to avoid coking. The fire bed to maintain the homogeneous combustion, to avoid burning fire bed obliquely. 6. The residence time of the fuel on the grate in less than 30 minutes.

Well designed and optimized the small series main parameters of dzl chain grate coal fired steam boiler maintenance check before delivery of submersible pumps confirm Henan fast boiler us with all the main parameters of the steam boiler optimization design and delivery of well maintenance check before confirming with submersible pumps steam boiler with other boiler Like products, in order to improve the combustion efficiency of the boiler must optimize the product, this article lists the following items index to optimize the design parameters and performance indicators as steam hot water boiler for reference purposes only. (1) to ensure safe operation of the hot water boiler steam: hot water boiler steam integral part life more than 30 years, the life by wear of the heating surface reaches more than 15 years. (2) Operation Economy excellent hot water boiler steam: Steam hot water boiler efficiency of 91% -93%, 99% combustion efficiency; small soda system flow resistance, reducing the power consumption of the feed pump; reduced gas side resistance losses, reducing blower, fan, and other auxiliary equipment mill power consumption. (3) has a good regulation performance: adjusting the combustion, steam temperature adjustment, like the boiler drum water level regulator flexible and effective. (4) investment cost savings: Enhanced heat transfer, reduce the consumption of metal, especially a reduction in the consumption of advanced metallic materials; under the premise of ensuring product quality, reduce manufacturing, transportation, construction and maintenance, operating costs. (5) High Reliability Run: available more than 90%, fewer unplanned downtime; fire, deflagration, and no accident slagging operation of the steam boiler hot water; heating surface leakage and over-temperature occurs, tube rupture. (6) has a good load following properties: rapid start and stop, load change quickly. (7) running stability: stable operation of the steam boiler parameters, thermal stress is small and easy to adjust automatically with coal and load changes. (8) slight heating surface wear, less fouling, corrosion, emissions meet environmental requirements. Check well before delivery inspection confirmed ① out with submersible well pumps, valves, and pre-population with submersible pumps line valve closed; ② confirmed wells with submersible pump inlet line valve closed temporary purged with nitrogen, removal of temporary hose, cap installed; ③ confirmation discharge line valve closed torch; ④ confirm the submersible well pump has been fully emptied medium (neat) with; ⑤ discharge line to confirm a closed valve closed; ⑥ confirmed vent valve opening (Ming row); ⑦ confirm submersible well pump body temperature was lowered to room temperature; ⑧ contact operating position within the pump power corresponding to the apparatus; ⑨ card to send electrical power plant, the pump power; ⑩ confirm that the pump motor off.

The picture shows the fast boiler processing plant located in the plain areas, plus catch up period is for a residential area of ​​Beijing for the production of low concentration of nitrogen product water tube boiler heating in winter, as scheduled in 2018 to ensure that heating at the same time, to meet the 20 mg / m require extremely low emissions of nitrogen oxides, Beijing air emission standards applicable to other regions 30 mg / cubic meter.

New type DZL Water Cooling Arch Chain Grate Steam Boiler

New type DZL Water Cooling Arch Chain Grate Steam Boiler. Rated Capacity: 2~10 t/h . Rated Pressure: 0.8~3.8 Mpa Fuel: II class bituminous coal, meager coal, anthracite coal, etc.

Learn More

DZL Steam Boiler,Coal Steam Boiler

DZL Coal Steam Boiler is a new eco-friendly and energy-saving product.The DZL chain grate stoker boiler can be automatic burning.It has Single drum,water tube and fire tube boiler.It is called as a revolution of industrial boilers by domestic and foreign experts.

Learn More

DZL Chain Grate Coal Fired Hot Water Boilers | Reliable Steam

DZL Chain Grate Coal Fired Steam Boiler is single drum three-return water tube and fire tube steam boiler. It adopt chain grate coal feeding design. Save a lot of labour work for worker. During the boiler working, worker just need to add coal every two hours. Both sides of the wall around the furnace are radiation heating surface.

Learn More

DZL Chain Grate Coal Fired Steam Boilers | Coal Fired Boilers

DZL Chain Grate Coal Fired Steam Boilers adopt chain grate or travelling grate fuel feeding design. It adopt horizontal three pass water tube and fire tube structure. DZL chain grate coal fired boiler realize automatic fuel feeding and slag removing process, which save a lot of labor work.

Learn More

Chain Grate Boilers, coal fired boiler, coal fired boiler

Chain Grate Boiler. Chain Grate Boilers fuel can be coal, lean coal, biomass, Coal fired boiler types have DZL, SZL, SHL, DHL, get the coal fired chain grate boiler price now. GET A QUOTECHAT ONLINE. DZL Packaged Chain Grate Boiler DZL Packaged Chain Grate Boiler Capacity: 2-10 t/1.4-7 MW. Pressure: 1.6MPa. Fuel: Bituminous Coal, Anthracite Coal.

Learn More

DZL Series Coal Fired Chain Grate Boiler--

DZL chain grate coal fired boiler design adopts the latest research product, " Second Prize of Advance Awarded by Xi'an Jiaotong University ", the back arch is low and long and the part near the exit is inverse inclined type, while the front arch is 45 inclined type, they together from a downside "α" flame structure, which makes the lean coal combustion easier and it can adjust itself to a wide range of coal types.

Learn More

coal boiler

The steam boilers produced by for coal-fired power stations have corner tube chain grate boilers and circulating fluidized bed boilers. 35 ton coal fired cfb boiler for chemical plant, rubber industry, paper industry, power generation has advantages of wide fuel adaptability, high combustion efficiency,

Learn More

DZL Chain Grate Coal Fired Steam Boilers | Coal Fired Boilers

DZL Chain Grate Coal Fired Steam Boilers adopt chain grate or travelling grate fuel feeding design. It adopt horizontal three pass water tube and fire tube structure. DZL chain grate coal fired boiler realize automatic fuel feeding and slag removing process, which save a lot of labor work.

Learn More

DZL Biomass Fired Chain Grate Boiler - china-boilers.com

DZL Series solid fuel fired boiler is drum boiler with both water tubes and fire tubes, the combustion equipment is chain grate (small scale flaker is available), has the advantages of feed mechanically, strong adaptability of different fuels, low coal leakage, and convenient maintenance.

Learn More

advantages of the chain grate stoker fired boiler

The new Hurst Boiler chain grate-type stoker system permits a wide range of water tubed boiler-type water membrane and a two-pass fire tube scotch marine vessel. This vessel's advantages over standard water tube boilers include much

Learn More

DZL chain grate boiler,chain grate boiler, corner tube chain

DZL chain grate coal fired boiler design adopts the latest research product, " Second Prize of Advance Awarded by Xi'an Jiaotong University ", the back arch is low and long and the part near the exit is inverse inclined type, while the front arch is 45 inclined type, they together from a downside "α" flame structure, which makes the lean coal combustion easier and it can adjust itself to a wide range of coal types.

Learn More

DZL series coal-fired steam boiler - Coal-fired boilers

DZL series package boilers are horizontal three-pass water & fire tube boilers with a chain grate stoker structure. Threaded pyrotechnic tubes are arranged in the drum to form a convection heating surface, while the drum and the water walls on both sides form a radiation heating surface in the furnace.

Learn More

DZL Chain Grate Biomass Fired Steam Boiler - China Best

DZL Chain Grate Biomass Fired Steam Boiler Features: The body adopts single drum structure, water tube and fire tube mixed design, full layout of heating surface and high thermal efficiency; Mechanized combustion; Environment friendly and energy saving; Complete auxiliaries and high self-control; The body and the base are separately delivered.

Learn More

Industrial Coal Steam Boiler,DZL Coal Fired Steam Boiler

The DZL coal fired steam boiler can be used for the following business: Chemical plant,Textile plant,Food & Beverage,Garment manufacturing,Paper Plant,Printing and dyeing mill,Cement Plant,Fertilizer plant,Feed mills,Rubber factory.Schools,Hotel,Bath Center,Swimming Pool,Hospital,Hotel,etc.

Learn More

Chain Grate Coal Fired Boiler - vvcollege.in

Coal Fired Stoker Boiler. DZL series coal fired stoker boiler is single drum, the combustion equipment is chain grate stoker. Water wall tubes at left and right sides of furnace are the radiated heating area. the two wings at furnace and screw fire tube in the

Learn More

Leave your email

We will contact you in the first time and choose the right boiler model for you and provide a reasonable solution.